Vivace Boat Information Book Web Version (BIB) (Rev February 13, 2014)
Revision 6 Page | 25
Fuel System Information (procedures for correcting engine stoppage due to fuel
contamination are below)
Fuel type: Diesel
Fuel consumption: Approximately .5 gallons per hour at 3000 rpm
Fuel System Description (Description of operator serviceable components only.
See the last pages of this section for schematic diagrams and detailed
description of the entire system)
1. 14 gallon tank in port lazarette. Quantity sensing by float and transducer.
2. Fill port on port side near primary winch
3. Tank vent on port transom.
4. Primary filter (3 or 10 micron may be used)
a. Filters fuel coming from tank and separates water and sediment.
(See maintenance procedures below.)
b. The Vivace spares box contains a new element.
5. Lift pump (visible through quarter berth access door)
a. Operates at relatively low pressure, 2535 psi.
b. Moves fuel from tank, through primary filter to engine.
c. Diaphragm is potential single point failure and must be periodically
changed.